For Schematic Diagram
• Refer to page 4-69 for printed wiring board.
2
3
4
1
RD-058 BOARD(5/13)
A
CARIB,POWER
-REF.NO.:20,000 SERIES-
XX MARK:NO MOUNT
:Voltage measurement of the CSP IC
and the Transistors with
mark,is
not possible.
B
R603
NO MARK:REC/PB MODE
33
R607
4700
R604
33
PB_MCK_3
R605
33
R608
4700
C
R606
33
55
TO(12/13)
SPDIF_HDMI
91
SPDIF_AV
TO(12/13)
D
PB_MCK_1
59
TO(9/13)
REC_MCK_2
E
SDR_A10
SDR_A11
SDR_A12
SDR_BA0
SDR_BA1
SDR_CLK
SDR_CKN
SDR_RAS
SDR_CAS
F
60
TO(6/13)
SDR_WE
B+
SDR_CKE
SW2.5V
SDR_DQS0
B+
SDR_DQS1
SW1.8V
63
B+
TO(7/13)
SW3.3V
SDR_DM0
SDR_DM1
DGND
SW2.5V
SDR_DQ0
SDR_DQ1
64
TO(11/13)
SW3.3V
SDR_DQ2
SDR_DQ3
G
DGND
SDR_DQ4
SDR_DQ5
SW2.5V
SDR_DQ6
SDR_DQ7
SW1.8V
SDR_DQ8
65
SDR_DQ9
TO(12/13)
SW3.3V
SDR_DQ10
DGND
SDR_DQ11
SDR_DQ12
UNSW6V
SDR_DQ13
SDR_DQ14
SH_SW5VA
SDR_DQ15
H
SH_SW1.5VA
SW3.3V
6
TO(1/13)
JTAGTMS
SH_SW3.3V
57
TO(13/13)
JTAGTCK
DGND
VDCTDO
SW3.3V
XCARRST2
34
SH_SW3.3V
TO(3/13)
DGND
XCARINT0
17
TO(1/13)
XCARINT1
I
SW3.3V
XCARCS0
49
TO(4/13)
SH_SW3.3V
SWDACK0
DGND
XSWDREQ0
48
TO(4/13)
SW3.3V
TO(9/13,
66
10/13)
DGND
XCARCS1
CARRDY
SH_SW3.3V
67
TO(13/13)
DGND
DAC_DATA
J
SH_SW3.3V
DAC_BCK
25
TO(2/13)
DGND
DAC_LRCK
58
TO(9/13)
SRC_BCK
SRC_LRCK
SRC_DATA
IC1102
BA00HC5FP-E2
K
IC1102
1
2
6
4
5
1.2V REG
R1124
0
2W
SH_SW3.3V
B+
_SH_SW1.5V
B+
UNSW6V
FL601
B+
L
SW1.8V
L1101
R1125
62
10uH
TO(12/13)
B+
0
_SW2.5V
R1108
B+
0
SW3.3V
SH_SW5VA
DGND
C1107
R1106
C1108
C1109
1u
20k
1u
100u
B
± 0.5%
B
4V
61
TO(6/13)
SW2.5VB_DDR
M
N
16
5
6
7
8
9
IC606
BUFFER
IC606
SN74LVC08APWR
1.6
3.2
R667
R661
1A
VCC
0
22
1W
3.2
1B
3A
R625
C628
C626
4700
10u
0.1u
B+
1.6
3.2
16V
B
1Y
3B
1.6
R662
2A
3Y
B+
R660
R631
22
22
3.2
0
0
2B
4A
R626
4700
1.6
3.2
2Y
4B
0
GND
4Y
C607
0.1u
B
R632
47
R635
0
1W
R616
68
R615
R637
0
0
N22
1W
1W
C10
D10
RB604
C660
22x4
100p
E11
2
1
SDR_A0
B26
4
3
SDR_A1
D25
6
5
SDR_A2
8
7
C26
(N22)NC
SDR_A3
N5
(N5)VSSC
(C10)AUOACK
RB605
D24
(D24)SDC_SA3
(D10)AUOBCK
C25
(C25)SDC_SA4
(E11)AUO_DO
22x4
2
1
SDR_A4
P22
(P22)VSSC
(B26)SDC_SA0
4
3
SDR_A5
6
5
F22
(F22)SDC_SA5
(D25)SDC_SA1
SDR_A6
E23
(E23)SDC_SA6
(C26)SDC_SA2
8
7
C613
SDR_A7
0.1u B
P25
(P25)VDD25I
RB606
H22
(H22)SDC_SA7
22x4
2
1
SDR_A8
G22
(G22)SDC_SA8
4
3
SDR_A9
D23
6
5
(D23)SDC_SA9
P5
(P5)VSSO
8
7
C23
(C23)SDC_SA10
B25
(B25)SDC_SA11
B24
(B24)SDC_SA12
D22
(D22)SDC_BA0
E21
(E21)SDC_BA1
R609
RB601
22x4
A24
(A24)SDC_CK
22
A25
(A25)SDC_CKN
22
E17
(E17)SDC_VREF
R620
B22
(B22)SDC_RAS
R610
R621
C609
R5
(R5)VDDC
22
22
0.1u B
22
A21
(A21)SDC_CAS
R611
SDR_CS
E20
(E20)SDC_CS0
R622
22
22
T22
(T22)VDD25O
R612
C608
JL606
B23
(B23)SDC_CS1
R623
22
0.1u
T24
(T24)VDD25I
B
A20
(A20)SDC_WE
R613
T26
(T26)VDD25O
22
R624
A23
(A23)SDC_CKE
22
D21
(D21)SDC_DM0
C21
(C21)SDC_DM1
R614
B21
(B21)SDC_DQS0
RB602
B20
(B20)SDC_DQS1
22
22x4
U22
(U22)NC
C20
(C20)SDC_DQ0
D20
(D20)SDC_DQ1
B19
(B19)SDC_DQ2
D19
(D19)SDC_DQ3
RB603
C610
22x4
0.1u B
U3
(U3)VDD33O
E19
(E19)SDC_DQ4
D18
(D18)SDC_DQ5
D17
(D17)SDC_DQ6
C18
(C18)SDC_DQ7
RB607
8
B18
(B18)SDC_DQ8
7
V23
(V23)VDD25I
22x4
6
5
C17
(C17)SDC_DQ9
4
3
A17
(A17)SDC_DQ10
2
1
A18
(A18)SDC_DQ11
8
7
C16
(C16)SDC_DQ12
C611
V4
(V4)VDD33I
6
5
0.1u
B
D16
(D16)SDC_DQ13
4
3
D15
(D15)SDC_DQ14
2
1
C15
(C15)SDC_DQ15
RB608
(AE2)IC1_TDO
22x4
AE2
AB6
(AB6)IC1_TDI
CARTDO
CARTDO
AD3
(AD3)IC1_TCK
AF2
(AF2)IC1_TMS
JTAGTMS
AC4
(AC4)IC1_BKTG
JL601
AC5
(AC5)IC2_TDO
JTAGTCK
JL602
AE1
(AE1)IC2_TDI
JL603
VDCTDO
AD4
(AD4)IC2_TCK
JL604
AA5
(AA5)IC2_TMS
JL605
AE3
(AE3)IC2_BKTG
XCARRST2
C7
(C7)HST_PERR
R618
Y23
(Y23)VDD25I
56
A5
(A5)HST_DACK
B5
(B5)HST_SERR
C5
(C5)HST_DREQ
A6
(A6)HST_INT0
B6
(B6)HST_INT1
R627
56
E9
(E9)HST_CS0
L11
(L11)VSSC(THERMAL)
R619
L12
(L12)VSSC(THERMAL)
56
L13
(L13)VSSC(THERMAL)
L14
(L14)VSSC(THERMAL)
L15
(L15)VSSC(THERMAL)
L16
(L16)VSSC(THERMAL)
R3679
10k
M11
(M11)VSSC(THERMAL)
M12
(M12)VSSC(THERMAL)
M13
(M13)VSSC(THERMAL)
M14
(M14)VSSC(THERMAL)
M15
(M15)VSSC(THERMAL)
M16
(M16)VSSC(THERMAL)
N11
(N11)VSSC(THERMAL)
DAC_DATA
N12
(N12)VSSC(THERMAL)
N13
(N13)VSSC(THERMAL)
N14
(N14)VSSC(THERMAL)
DAC_BCK
N15
(N15)VSSC(THERMAL)
N16
(N16)VSSC(THERMAL)
DAC_LRCK
P11
(P11)VSSC(THERMAL)
P12
(P12)VSSC(THERMAL)
SRC_BCK
P13
(P13)VSSC(THERMAL)
SRC_LRCK
P14
(P14)VSSC(THERMAL)
P15
(P15)VSSC(THERMAL)
SRC_DATA
P16
(P16)VSSC(THERMAL)
R11
(R11)VSSC(THERMAL)
(T11)VSSC(THERMAL)
R12
(R12)VSSC(THERMAL)
(T12)VSSC(THERMAL)
(T13)VSSC(THERMAL)
R13
(R13)VSSC(THERMAL)
R14
(R14)VSSC(THERMAL)
(T14)VSSC(THERMAL)
(T15)VSSC(THERMAL)
R15
(R15)VSSC(THERMAL)
R16
(R16)VSSC(THERMAL)
(T16)VSSC(THERMAL)
T11
T12
T13
T14
T15
T16
1.2V
FL602
2.6V
3.5V
FL603
B+
B+
C602
C603
C604
C605
C606
0.1u
10u
0.1u
10u
0.1u
B
16V
B
16V
B
C612
0.1u
B
38
TO(3/13)
40
TO(3/13,7/13,12/13)
4-45
10
11
12
13
68
TO(6/13)
RB623
22x4
C630
R672
R674
0.1u
0
0
B
1W
1W
IC601
ATA I/F
IC601
CXD4702GB
CSP(CHIP SIZE PACKAGE)IC
C614
R647
C618
0.1u
0
47u
B
1W
4V
TO(3/13,
TO(3/13,
41
TO(3/13,7/13)
36
35
42
70
7/13,
TO(9/13)
7/13)
11/13)
TO(3/13,
7/13)
14
15
16
17
18
92
73
93
TO(7/13,10/13)
TO(7/13)
TO(10/13)
AT1_AD3
R692
0
AT1_AD4
1W
AT1_AD2
AT1_AD0
AT1_AD1
AT1_INT
AT1_DACK
AT1_RDY
R3629
R2311
RB636
68
0
VCK
22x4
70
AT1_RD
7
60
AF4
6
50
AE4
5
40
AF5
4
AE5
AT1_WE
D14
3
30
AD5
AT1_DREQ
20
NC(D12) D12
2
10
VDI_D7(AF4)
VDI_D2(AE6)
AE6
1
00
VDI_D6(AE4)
VDI_D1(AD6) AD6
0
VDI_D5(AF5)
VDI_D0(AC7)
AC7
H
RB637
VDI_D4(AE5)
VDI_HD(AB8) AB8
V
22x4
NC(D14)
VDI_VD(AB9)
AB9
F
VDI_D3(AD5)
VDI_FID(AB7) AB7
VDD33O(C6)
C6
CRB_AT1_D15
VDI_CK(AF3) AF3
C641
VDD33O(C4)
C4
CRB_AT1_D0
70
0.1u
VDO_D7(AF7) AF7
60
B
VDO_D6(AE7)
AE7
50
CRB_AT1_D14
VDO_D5(AD7) AD7
VDD25O(C24)
C24
CRB_AT1_D1
40
VDO_D4(AF8) AF8
C642
VDD25O(C22)
C22
CRB_AT1_D13
30
0.1u
VDO_D3(AE8) AE8
20
B
VDO_D2(AD8)
AD8
CRB_AT1_D2
VDD33I(C2)
C2
VDD25I(C19)
C19
CRB_AT1_D12
10
R3619
R3637
VDO_D1(AE9) AE9
00
10k
VDO_D0(AD9)
AD9
22
CANNAZHD
CRB_AT1_D3
VDO_HD(AC11) AC11
VDO_VD(AB11)
AB11
R3630
CRB_AT1_D11
R3620
NC(C14) C14
22
22
VDO_FID(AC10)
AC10
CARNAZVCK
CRB_AT1_D4
R3631
22
VDO_CKO(AF6) AF6
R3601
VDO_CKI(AB10)
AB10
CRB_AT1_D10
0
1W
CRB_AT1_D15
AT1_D15(AD14) AD14
CRB_AT1_D14
AT1_D14(AC14)
AC14
CRB_AT1_D5
CRB_AT1_D13
AT1_D13(AF13) AF13
C646
VDD33O(B8)
B8
CRB_AT1_D9
0.1u B
CRB_AT1_D12
AT1_D12(AE13) AE13
CRB_AT1_D11
AT1_D11(AC12)
AC12
CRB_AT1_D10
CRB_AT1_D6
AT1_D10(AE12) AE12
CRB_AT1_D9
AT1_D9(AD11)
AD11
CRB_AT1_D8
CRB_AT1_D8
AT1_D8(AE10) AE10
CRB_AT1_D7
AT1_D7(AF10)
AF10
CRB_AT1_D7
CRB_AT1_D6
AT1_D6(AF11) AF11
CRB_AT1_D5
AT1_D5(AF12)
AF12
CRB_AT1_D4
AT1_D4(AD12) AD12
CRB_AT1_D3
AT1_D3(AB12)
AB12
CRB_AT1_D2
AT1_RST
AT1_D2(AC13) AC13
CRB_AT1_D1
AT1_D1(AE14)
AE14
CRB_AT1_D0
AT1_D0(AF14) AF14
AT1_OE(AC16)
AC16
AT1_AD4
JL623
AT1_CSN1(AE18) AE18
VDD25I(B17)
B17
AT1_AD3
AT1_CSN0(AF18) AF18
C643
NC(B15)
B15
0.1u
NC(B14) B14
B
AT1_AD2
AT1_DA2(AF17)
AF17
AT1_AD1
AT1_DA1(AF16) AF16
AT2_AD3
AT1_AD0
AT1_DA0(AE17)
AE17
C644
VDD33I(B10) B10
0.1u
B
AT1_INT
AT2_AD4
AT1_INTREQ(AD16)
AD16
AT1_DACK
AT1_DMACK(AD17) AD17
AT1_RDY
AT2_AD2
AT1_IORDY(AE16)
AE16
AT1_RD
AT1_DIOR(AF15) AF15
AT1_WE
AT2_AD0
AT1_DIOW(AD15)
AD15
AT1_DREQ
AT1_DMARQ(AC15) AC15
AT1_RST
AT1_XRST(AF9)
AF9
ATA_MODE(AF22) AF22
AT2_AD1
VSSO(AF26)
AF26
NET_CK(AF25) AF25
CRB_AT2_D15
AT2_D15(AD20)
AD20
CRB_AT2_D14
AT2_D14(AB20) AB20
CRB_AT2_D13
AT2_INT
AT2_D13(AC20)
AC20
CRB_AT2_D12
AT2_D12(AC21) AC21
CRB_AT2_D11
AT2_D11(AD22)
AD22
CRB_AT2_D10
AT2_D10(AE23) AE23
CRB_AT2_D9
AT2_DACK
AT2_D9(AC23)
AC23
CRB_AT2_D8
AT2_D8(AE24) AE24
CRB_AT2_D7
AT2_D7(AF24)
AF24
CRB_AT2_D6
AT2_D6(AD24) AD24
AT2_RDY
CRB_AT2_D5
AT2_D5(AF23)
AF23
CRB_AT2_D4
AT2_D4(AD23) AD23
CRB_AT2_D3
AT2_D3(AE22)
AE22
CRB_AT2_D2
AT2_D2(AB21) AB21
CRB_AT2_D1
AT2_RD
AT2_D1(AF21)
AF21
CRB_AT2_D0
AT2_D0(AB19) AB19
VSSO(AF1)
AF1
AT2_OE(AF19) AF19
AT2_WE
AT2_AD4
AT2_CSN1(AB17)
AB17
JL624
AT2_AD3
AT2_CSN0(AC17) AC17
AT2_AD2
AT2_DA2(AB18)
AB18
AT2_AD1
AT2_DA1(AD18) AD18
AT2_DREQ
AT2_AD0
AT2_DA0(AC18)
AC18
AT2_INT
AT2_INTREQ(AE19) AE19
AT2_DACK
AT2_DMACK(AD19)
AD19
AT2_RDY
AT2_IORDY(AC19) AC19
AT2_RD
AT2_DIOR(AF20)
AF20
AT2_WE
AT2_DIOW(AE21) AE21
AT2_DREQ
AT2_DMARQ(AE20)
AE20
AT2_RST
AT2_XRST(AE25) AE25
STI_D7(AA1)
AA1
STI_D6(AA2) AA2
STI_D1(W4)
STI_D5(AA3)
AA3
STI_D0(V3)
STI_D4(Y2) Y2
STI_XREQ(U5)
STI_D3(Y3)
Y3
C645
VDD33O(AE11)
STI_D2(W3) W3
STI_CK(AB1)
0.1u
VDD33I(AE15)
AE15
STI_EN(T5)
W4
B
V3
U5
AE11
JL627
AB1
T5
B+
R654
10k
C619
C620
0.1u
0.1u
B+
B
B
4-46
RDR-HX1010
19
20
21
CN602
40P
40
GND
JL625
39
DASP
38
IDE_A3(CS1)
37
IDE_A4(CS0)
36
IDE_A2
RB654
33x4
35
IDE_A0
34
NC
R3650
33
33
IDE_A1
32
IDE_HD16
R3651
82
31
IDE_INT
R3674
10k
R3652
30
GND
22
29
IDE_DACK
28
CSEL
R3653
82
27
IDE_IORDY
R3672
1k
26
GND
R3654
22
25
IDE_R
R3655
24
GND
22
R3675
23
IDE_W
5600
DVD
22
GND
R3656
UNIT
82
21
IDE_DREQ
C656
0.1u
20
NC
B
19
GND
18
IDE_D15
17
IDE_D0
16
IDE_D14
RB655
220x4
15
IDE_D1
14
IDE_D13
13
IDE_D2
RB656
12
IDE_D12
220x4
11
IDE_D3
10
IDE_D11
9
IDE_D4
RB657
8
IDE_D10
220x4
7
IDE_D5
6
IDE_D9
5
IDE_D6
RB658
4
IDE_D8
220x4
3
IDE_D7
C655
0.1u
R3657
2
GND
B
33
1
IDE_RST
C658
CN603
40P
0.1u
B
40
GND
JL626
39
DASP
38
IDE_A3(CS1)
37
IDE_A4(CS0)
RB659
36
IDE_A2
150x4
35
IDE_A0
R3658
34
SATA_RST
150
33
IDE_A1
R3659
32
IDE_HD16
220
31
IDE_INT
R3676
10k
R3660
30
GND
22
29
IDE_DACK
C657
0.1u
28
CSEL
R3661
B
220
27
IDE_IORDY
R3662
26
GND
R3673
22
1k
25
IDE_R
24
GND
R3663
TO
22
CN-243 BOARD
23
IDE_W
R3677
CN1802
5600
22
GND
(SEE PAGE
21
IDE_DREQ
4-27)
R3664
82
20
NC
19
GND
CRB_AT2_D15
18
IDE_D15
CRB_AT2_D0
17
IDE_D0
CRB_AT2_D14
16
IDE_D14
RB660
220x4
CRB_AT2_D1
15
IDE_D1
CRB_AT2_D13
14
IDE_D13
CRB_AT2_D2
13
IDE_D2
CRB_AT2_D12
RB661
12
IDE_D12
CRB_AT2_D3
220x4
11
IDE_D3
CRB_AT2_D11
10
IDE_D11
CRB_AT2_D4
9
IDE_D4
CRB_AT2_D10
RB662
8
IDE_D10
CRB_AT2_D5
220x4
7
IDE_D5
CRB_AT2_D9
6
IDE_D9
CRB_AT2_D6
5
IDE_D6
CRB_AT2_D8
RB663
4
IDE_D8
220x4
CRB_AT2_D7
3
IDE_D7
R3665
2
GND
33
AT2_RST
1
IDE_RST
CARIB, POWER
RD-058 (5/13)