11 Device Information
1
Type and order code
2
Design
2.1
Controller
2.2
Installation location / degree of protection according to EN 60529
2.3
Antifreeze condensate tray / heating water
2.4
Performance levels
3
Operating limits
3.1
Heating water flow / return flow
3.2
Air (heat source)
4
Performance data / flow rate
4.1
Heating water flow rate
/ internal pressure differential
Minimum heating water flow rate
2 3
4.2
Heat output / COP
4.3
Sound power level device / outdoors
4.4
Sound pressure level at a distance of 1 m (indoors)
4.5
Air flow rate
with an external static pressure differential of
5
Dimensions; weight and filling quantities
5.1
Device dimensions without connections
5.2
Device connections to heating system
5.3
Weight of the transportable unit(s) incl. packing
5.4
Refrigerant; total filling weight
5.5
Lubricant; total filling quantity
6
Electrical Connection
6.1
Nominal voltage; fuse protection
6.2
Starting current with soft starter
6.3
Nominal power consumption
A2/W35 / max. consumption
Nominal current A2/W35 / cos
6.4
6.5
max. power consumption of compressor protection
(per compressor)
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
1. The heat circulating pump and the heat pump manager must always be ready for operation.
2. These data indicate the size and capacity of the system according to EN 255 (10K at A2) and EN 14511 (5K at A7) without weather-proof protective cover. For an analysis of the
economic and energy efficiency of the system, other parameters, in particular the defrosting capacity, the bivalence point and the regulation, should also be taken into considera-
tion. The specified values have the following meaning, e.g. A7 / W35: External air temperature 7 °C and heating water flow temperature 35 °C.
3. The data are valid for "free extracting" and "free venting" installation; fan in star connection.
4. 2-compressor operating mode
5. 1-compressor operating mode
6. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
7. With an external static pressure differential greater than 15 PA it is recommended to operate the fan in delta connection.
8. see CE declaration of conformity
www.dimplex.de
°C
°C
A7 / W35/30
m³/h / Pa
A7 / W45/38
m³/h / Pa
A7 / W55/45
m³/h / Pa
at A-7 / W35
kW / ---
kW / ---
at A2 / W35
kW / ---
kW / ---
at A7 / W35
kW / ---
kW / ---
at A7 / W55
kW / ---
kW / ---
at A10 / W35
kW / ---
kW / ---
dB(A)
6
dB(A)
m³/h / Pa
m³/h / Pa
H x W x L mm
Inch
kg
type / kg
type / litre
V / A
A
2 4
kW
4
A / ---
W
LI 40AS
External
Indoors / IP 21
Heated / yes
up to 58 ± 2 / from 18
-25 to +35
6.2 / 3900
4.3 / 1900
3.0 / 950
EN 255
4
24.3 / 3.1
5
13.8 / 3.2
4
29.6 / 3.9
5
17.1 / 4.0
4
5
4
5
4
38.5 / 4.8
5
22.0 / 5.0
64 / 70
11000 / 0
9500 / 15
2100 x 1735 x 952 (750)
1 1/2'' external thread
R404A / 11.8
Polyolester (POE) / 4.1
400 / 25
7.9 / 12.6
14.2 / 0.8
70; thermostatically controlled
Reverse circulation
11
1
2
EN 14511
23.8 / 3.0
13.5 / 3.1
29.3 / 3.8
16.8 / 3.9
35.7 / 4.4
20.0 / 4.6
33.1 / 2.7
17.6 / 2.7
38.1 / 4.7
21.7 / 4.9
60
7
590
30
8
EN-9