Page 1
Figure 1 Control Switches Relay Board The layout of an EC3.0 relay board is shown below. It has five relays, one 12 position terminal block, three 10 amp fuses, two connectors and seven LED indicators. The function of each component are listed in table below...
EC3.0 system only displays the temperature between 60 ºF and 90 ºF. If the actual temperature is lower than 60 ºF, the display will show “Lo”. If the temperature is above 90ºF, the display will show “Hi”.
Fan Speed Control EC3.0 system has two speed control modes. Auto fan speed control and manual fan speed control. In manual fan speed control, there are three settings High, Medium and Low. In auto fan speed control mode, evaporator blower speed is controlled based on the temperature differential between Tin and Tset.
Beside safety switches, EC3.0 also monitors two other electrical faults: low clutch voltage and blown fuse. The EC3.0 system senses the voltage on terminal 8 (clutch power input terminal). If the voltage on terminal drops below 11.9 vdc, EC3.0 system will turn off condenser output and compressor clutch output and display “Lu”...
Slave board configuration In some large systems where the electrical load exceeds the current capability of a single board, a slave board can be used. A typical wiring diagram is 5031xxxx. In a slave system, the switches are connected to the master board and the slave board is connected to the master board through a harness 701442.