Chapter 7
The blade vibration unit is driven for the following:
- after initial multiple rotation imitated by turning on the main power (5 or 1 vibration)
- at time of STOP sequence (1 vibration)
- during wire cleaning associated with pre-transfer, transfer, and separation (1 vibration)
1 vibration: ON for 0.6 sec
5 vibrations: ON for 0.6 sec, OFF for 0.3 sec
SERVICE MODE:
You can check the activation of the blade vibration unit in service mode: COPIER>FUNCTION>PART-
CHK>MTR.
7.6.2 Detecting the Waste Toner (case full condition)
The following shows the construction of the control system associated with the detection of the state of
the waste toner bottle (full):
1
2
3
4
5
6
7
14
1
2
3
14
1
14
15
7-18
J514B
0V
MAIN_MOTOR_FG
MAIN_MOTOR_ON
5V
0V
(front)
WASTE_TONER_OVER_PS
J514A
0V
5V
J512B
Waste toner bottle full sensor(PS19)
0V
WASTE_TONER_PACKED_DTC
Main motor
M1
Waste toner lock sensor(MSW2)
Waste toner bottle
The bottle grows heavier
as more and more waste
toner collect, causing the
waste toner bottle full
sensor to detect the flag.
F-7-25
0010-8060