free hit counter

Controlling The Output To Suit The Environment - Canon imageRUNNER 7095 Service Manual

Hide thumbs Also See for imageRUNNER 7095:
Table of Contents

Advertisement

Chapter 7

7.8.1.2 Controlling the Output to Suit the Environment

The transfer guide bias is optimized to suit the environment (identified with reference to the data from the
environment sensor).
A bias of the same polarity as the toner is
applied in sync with the rotation of the
photosensitive drum.
Normally, +600 V is applied to prevent
adhesion of toner to the transfer guide.
SERVICE MODE:
- COPIER> OPTION> BODY> TRNSG-SW (transfer guide bias control mode switchover)
0: switches to +200 V in a high-humidity environment (default)
1: fix the transfer guide bias to +600 V
2: fix the transfer guide bias to +200 V
3: switches to +200 V in a normal humidity condition
4: switches to +200 V in a low humidity condition
Set it to '2' through '4' if a transfer fault is noted.
7-28
Normal/low humidity
High humidity
In a high humidity environment, paper tends to absorb moisture
(lower resistance), charging the paper in excess to affect transfer
(faulty transfer); as such, the output is decreased.
The photosensitive drum is rotating;
yet, paper is not being fed.
Transfer guide bias
Paper passing
+600
+200
F-7-37
Paper being fed
+600
+600
0010-8069