Chapter 7
7.10.1.3 Mounting the Process Unit
Keep the following in mind when mounting the
process unit [1] to the slide rail:
1) Be sure to match the notch [2] found at the tip
of the left slide rail against the front plate [3] of
the process unit.
2) Be sure to match the bend [4] at the front of the
right slide rail against the front plate [3] of the
process unit.
[2]
[3]
F-7-51
Waste toner can drop on the duplex unit when the
process unit is removed. After mounting the proc-
ess unit. be sure to slide out the duplex unit and
remove the waste toner.
7.10.2 Pre-Exposure Lamp
7.10.2.1 Removing the Pre-Exposure
Lamp Unit
1) Open the front cover.
2) Slide out the process unit.
Cover the drum with A3 paper or the like when
you have slid out the process unit.
7-36
0010-8812
[1]
[5]
[4]
0010-8819
3) Disconnect the connector [1], and remove the
two screws [2]; then, detach the preexposure
unit [3].
[1]
F-7-52
4) Remove the three screws [1], and detach the
pre-exposure holder [2]; then, detach the pre-
exposure lamp [3].
[1]
F-7-53
[3]
F-7-54
[2]
[3]