Selector
No.
1
Frequency band selection (lower
limit) for incoming calling signal (CI)
2
3
Frequency band selection (upper
limit) for incoming calling signal (CI)
4
5
|
No. of rings in AUTO ANS mode
8
Selectors 1 through 4: Frequency band selection for incoming calling signal (CI)
These selectors are used to select the frequency band of CI for activating the AUTO ANS facility.
In the French models, if the user sets the PBX to OFF from the control panel, the setting made by
selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even if
the setting made by these selectors does not apply, it will be printed on the configuration list.)
Selectors 5 through 8: No. of rings in AUTO ANS mode
These selectors set the number of rings to initiate the AUTO ANS facility.
WSW14
(AUTO ANS facility setting) (Not used.)
Function
App. 4-18
Setting and Specifications
No. 1
2
0
0
:
13 Hz
0
1
:
15 Hz
1
0
:
23 Hz
1
1
:
20 Hz
No. 3
4
0
0
:
30 Hz
0
1
:
55 Hz
1
0
:
70 Hz
1
1
: 200 Hz
No. 5
6
7
8
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
:
Fixed to once
:
1 to 6 times
:
1 to 8 times
:
2 to 8 times
:
1 to 2 times
:
1 to 3 times
:
1 to 4 times
:
1 to 5 times
:
2 to 3 times
:
2 to 4 times
:
2 to 5 times
:
2 to 6 times
:
1 to 10 times
:
2 to 10 times
:
3 to 5 times
:
4 to 10 times
Confidential

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcp540cnDcp750cwDcp330c

Table of Contents